THERMODYNAMIC PERFORMANCE OF A 285 MW GAS TURBINE UNIT UNDER VARYING OPERATING CONDITIONS

Authors

  • Idris A. Elfeituri University of Benghazi, Benghazi, Libya Author

DOI:

https://doi.org/10.66411/jer.v23i.306

Keywords:

Gas Turbine Performance, Ambient Effect, Part-load, Power Production

Abstract

The thermodynamic performance of a gas turbine unit mainly depends on the ambient and loading conditions. The difference between the actual power generated by a gas turbine and the design rated power is observed whenever it operates at site ambient conditions that vary from the stipulated ISO conditions or at part-loading operation. Consequently, its actual power output and thermal efficiency are different from its rated design values.

This paper is devoted to study the effects of ambient conditions variations, such as ambient temperature and relative humidity on gas turbine unit performance at different loads. For this work, the power plant chosen is a gas turbine unit of 285 MW installed  capacity. Mass and energy balance equations with typical specifications of the selected gas turbine unit have been used to develop the thermodynamic model. Based on this model, a computer program has been established and used to investigate the performance of the  unit  under  varying  ambient  and  loading  conditions.  These  include  ambient temperature, ranging from zero to 50 °C, relative humidity, ranging from zero to 100%, gas turbine load ranging from 25% to  100%  with turbine inlet temperature fixed at 1242°C. the results obtained showed that a degree (1°C) increase in ambient temperature, leads to 0.53% decrease in the net power output, 0.18 % decrease in the thermal efficiency and  0.195  %  increase  in  specific  fuel  consumption.  The  relative  humidity  has  a remarkable influence on net power output but almost none on thermal efficiency. 

256 125

References

[1] Bolland Olav. Thermal Power Generation. Department of Engineering Process Engineering. 2010; NTNU.

[2] General Electricity Company in Libya.

[3] Brooks F. J. GE Gas Turbine Performance Characteristics. NY. GE power Systems 2005.

[4] Ushiyama I. Theoretical Estimating the Performance of Gas Turbines Under Varying Atmospheric Conditions. ASME Journal of Engineering for Power 1976; 98: 69-78. DOI: https://doi.org/10.1115/1.3446116

[5] De Sa, S., Al Zubaidy. Gas turbine Performance at Varying Ambient Temperature. Applied Thermal Engineering 2011, 31: 2735-2739. DOI: https://doi.org/10.1016/j.applthermaleng.2011.04.045

[6] Al-ibrahim A., et al. Combustion Turbine Inlet Air Cooling Technologies and Performance in the Climate Conditions of Saudi Arabia. Proceeding of ECON; 2002: Nov. 2-3: Saudi Aramco Demmam.

[7] Ameri A., Hejazi S. H. The study of Capacity Enhancement of the Chabahar Gas Turbine Installation Using an Absorption Chiller. Applied Thermal Engineering 2011; 24: 59-68. DOI: https://doi.org/10.1016/S1359-4311(03)00239-4

[8] Jaber et Q M, Jaber J O, Khawaldah M A. Assessment of Power Augmentation from Gas Turbine Power Plants Using different Air Cooling Systems. Journal of Mechanical and Industrial Engineering 2007; 1: 7-15.

[9] Deng-Chem Sue, Chia-Chin Chuag. Engineering Design and exergy Analysis for Combustion Gas Turbine Based Power Generation System. Energy 2005; 29: 1183-1205. DOI: https://doi.org/10.1016/j.energy.2004.02.027

[10] Kam W Li, Priddy A P. Power Plant System Design. John Wiley and Sons 1985.

[11] Zapoor A., Golshan A. H. Performance Improvement of a Gas Turbine Cycle by Using a Desiccant Based Evaporative Cooling system. Energy 2008; 31: 2652- 2664. DOI: https://doi.org/10.1016/j.energy.2005.11.004

[12] Alhazmy M. M., Najjar Y. S. H. Augmentation of Gas Turbine Performance Using Coolers. Applied Thermal Engineering 2008; 24: 7415-429.

[13] HadikA. A. The impact of Atmospheric Conditions on Gas Turbine Performance. Transactions of ASME 1990; 112: 590-596. DOI: https://doi.org/10.1115/1.2906210

[14] Bassem g., et al. Performance of Gas Turbine Co-generation Power Desalting Plants Under Varying Operating Conditions in Kuwait. Heat Recovery Systems &CHP 1990; 10 (3): 243-253. DOI: https://doi.org/10.1016/0890-4332(90)90005-5

[15] Abam F., et al. The Effect of Ambient Temperature on Components Performance of an In-service Gas Turbine Plant using Exergy Method. Singapore Journal of Scientific research 2011; 1: 23-37. DOI: https://doi.org/10.3923/sjsres.2011.23.37

[16] FallahM. G. Effect of Ambient Temperature on the Thermodynamic Performance of a Combined Cycle. Journal of Engineering Research, Triply University 2011; 13: 35-48.

[17] Siemens Power Generation Co. Performance Curves for Sarir SGT5-PAC 4000F Gas Turbine Power Plant Under Ambient and Loading Conditions. Siemens Performance Data Catalogue 2010.

[18] Pulkrabek W. Engineering Fundamentals of the Internal Combustion Engine. 2nd ed. New York, prentice hall 2004. DOI: https://doi.org/10.1115/1.1669459

[19] Ongiro et al. Using the Aspen Plus shell to Simulate the Performance of Gas Turbines. Engineering System Design and Analysis 1994; 3: 57-64.

[20] Salan et al. Parametric Study of gas Turbine Cycle with Fogging System. Journal of Basrah Research 2007; 33 (4): 16-30.

[21] Oyedepo S. O. and Kilanko O. Thermodynamic Analysis of a Gas Turbine Power Plant Modeled with an Evaporative Cooler. International J. of Thermodynamic 2014; 17(1): 14-20. DOI: https://doi.org/10.5541/ijot.76988

[22] Aklilu B T., Gilani S I. Mathematical Modeling and Simulation of a Cogeneration Plant. Applied Thermal Engineering 2010; 30: 2545-2554. DOI: https://doi.org/10.1016/j.applthermaleng.2010.07.005

[23] Na Zhang, Ruixin Cai. Analytical Solutions and Typical Characteristics of Part Load Performance of a Single Shaft Gas Turbine and its Cogeneration. Energy Conversion and Management 2003; 43: 1323-1337. DOI: https://doi.org/10.1016/S0196-8904(02)00018-3

Downloads

Published

31-03-2017

Issue

Section

Articles

How to Cite

[1]
I. A. Elfeituri, “THERMODYNAMIC PERFORMANCE OF A 285 MW GAS TURBINE UNIT UNDER VARYING OPERATING CONDITIONS”, JER, vol. 23, pp. 145–162, Mar. 2017, doi: 10.66411/jer.v23i.306.