CONDITION MONITORING SYSTEM FOR WIND GENERATOR BASED ON THE EFFECTS OF THE GENERATOR PERMANENT TEMPERATURE

Authors

  • Khaled B. Abdusamad Department of Mechanical Engineering, Faculty of Engineering Garaboulli, AL-Mergeb University, Garaboulli-Libya Author
  • Tariq R. Aboalhol Department of Mechanical Engineering, Yefren HigherPolytechnic Institute, Yefren-Libya Author

DOI:

https://doi.org/10.66411/jer.v23i.307

Keywords:

Condition-Monitoring System, Permanent Magnet Temperature, Induced Electrical Torque, Magnetization Angle

Abstract

Due to the increased rate of failure of wind generators, condition-monitoring system plays  a  significant  role  in  overcoming  failures  resulting  from  the  harsh  operation conditions. The mathematical, thermal, and electrical analyses may be utilized to detect the faults of wind generators by monitoring the changes in their characteristics under different operation conditions. The behavior of the rotating permanent magnet of the generator can indicate the wind generator’s condition. For instance, the torque of the permanent  magnet  of  the  generator  is   affected  by  the   oscillation  of  the  magnet temperature. Therefore, monitoring the torque of the permanent magnet with respect to the rate of change in the permanent magnet temperature defines the generator health. Furthermore, the rate of change in the generator temperature is considered an additional indicator to define the health of the wind generators with respect to the induced electrical torque. That is because of the negative effect of the elevated generator temperature on the induced electrical torque. In this study, a different methodology has been adopted to implement a proper condition monitoring system on the wind generators by evaluating the rate of change in the generator temperature and permanent magnet temperature with respect to the induced electrical torque and the driving torque of the rotating permanent

magnet under different operation conditions. A case study, which is based upon collected data from actual measurements, is presented in this work in order to demonstrate the adequacy of the proposed model.

179 84

References

[1] J. Nilsson and L. Bertling, "Maintenance management of wind power systems using condition monitoring systems—life cycle cost analysis for two case studies," Energy Conversion, IEEE Transactions on, vol. 22, pp. 223-229, 2007. DOI: https://doi.org/10.1109/TEC.2006.889623

[2] A. Amayri, Z. Tian, and T. Jin, "Condition based maintenance of wind turbine systems considering different turbine types," in Quality, Reliability, Risk, Maintenance, and Safety Engineering (ICQR2MSE), 2011 International Conference on, 2011, pp. 596-600. DOI: https://doi.org/10.1109/ICQR2MSE.2011.5976683

[3] Y. Li, "Discussion on the principles of wind turbine condition monitoring system," in Materials for Renewable Energy & Environment (ICMREE), 2011 International Conference on, 2011, pp. 621-624. DOI: https://doi.org/10.1109/ICMREE.2011.5930888

[4] F. P. G. Márquez, A. M. Tobias, J. M. P. Pérez, and M. Papaelias, "Condition monitoring of wind turbines: Techniques and methods," Renewable Energy, vol. 46, pp. 169-178, 2012. DOI: https://doi.org/10.1016/j.renene.2012.03.003

[5] K. Alewine and W. Chen, "A review of electrical winding failures in wind turbine generators," in Electrical Insulation Conference (EIC), 2011, 2011, pp. 392-397. DOI: https://doi.org/10.1109/EIC.2011.5996185

[6] J. Li, X. Lei, H. Li, and L. Ran, "Normal Behavior Models for the Condition Assessment of Wind Turbine Generator Systems," Electric Power Components and Systems, vol. 42, pp. 1201-1212, 2014. DOI: https://doi.org/10.1080/15325008.2014.921954

[7] P. Guo, D. Infield, and X. Yang, "Wind turbine generator condition-monitoring using temperature trend analysis," Sustainable Energy, IEEE Transactions on, vol. 3, pp. 124-133, 2012. DOI: https://doi.org/10.1109/TSTE.2011.2163430

[8] L. M. Popa, B.-B. Jensen, E. Ritchie, and I. Boldea, "Condition monitoring of wind generators," in Industry Applications Conference, 2003. 38th IAS Annual Meeting. Conference Record of the, 2003, pp. 1839-1846. DOI: https://doi.org/10.1109/IAS.2003.1257819

[9] K. B. Abdusamad and W. D. Gao, "The application of heat transfer analysis in condition monitoring system of wind generator," in Power and Energy Engineering Conference (APPEEC), 2013 IEEE PES Asia-Pacific, 2013, pp. 1-7. DOI: https://doi.org/10.1109/APPEEC.2013.6837308

[10] K. B. ABDUSAMAD, D. W. Gao, and E. Muljadi, "The Influence of Heat Loss on Wind Generators to Implement Condition-Monitoring System Based on the Application of the Polynomial Regression Model," International Journal of Renewable Energy Research (IJRER), vol. 4, pp. 401-412, 2014.

[11] W. Yang, P. J. Tavner, and M. Wilkinson, "Condition monitoring and fault diagnosis of a wind turbine synchronous generator drive train," Renewable Power Generation, IET, vol. 3, pp. 1-11, 2009. DOI: https://doi.org/10.1049/iet-rpg:20080006

[12] K. B. Ma, J. R. Liu, C. McMichael, R. Bruce, D. Mims, and W. K. Chu, "Spontaneous and persistent rotation of cylindrical magnets levitated by Y-Ba-Cu- O superconductors," Journal of applied physics, vol. 70, pp. 3961-3963, 1991. DOI: https://doi.org/10.1063/1.349158

[13] T. L. Bergman, F. P. Incropera, and A. S. Lavine, Fundamentals of heat and mass transfer: John Wiley & Sons, 2011.

[14] A. Tveito and R. Winther, Introduction to partial differential equations: a computational approach vol. 29: Springer Science & Business Media, 2005.

[15] K. B. Abdusamad.Condition Monitoring System of Wind Turbine Generator, Doctoral dissertation, University of Denverm 2014.

[16] C. Kittel, Introduction to solid state physics: Wiley, 2005.

[17] O. D. Kellogg, Foun16dations of potential theory vol. 31: Springer Science & Business Media, 2012.

[18] Data of a variable speed wind turbine 600 KW rated power, three phase permanent magnetic type 440/660 V 60 Hz. Provided by Dr. Kathryn, Colorado School of Mines and the National Renewable Energy Laboratory, 2013.

[19] C. Lungoci and D. Stoia, "Temperature effects on torque production and efficiency of motors with NdFeB," parameters, vol. 2, 2008.

[20] L. Xin, L. Bin, X. Jianyuan, and T. Yun, "Notice of Retraction A Novel Power Predicting Model of Wind Farm Based on Double ANNs," in Power and Energy Engineering Conference (APPEEC), 2010 Asia-Pacific, 2010, pp. 1-4. DOI: https://doi.org/10.1109/APPEEC.2010.5448680

Downloads

Published

31-03-2017

Issue

Section

Articles

How to Cite

[1]
K. B. Abdusamad and T. R. Aboalhol, “CONDITION MONITORING SYSTEM FOR WIND GENERATOR BASED ON THE EFFECTS OF THE GENERATOR PERMANENT TEMPERATURE”, JER, vol. 23, pp. 163–176, Mar. 2017, doi: 10.66411/jer.v23i.307.