EJECTOR INCORPORATION TO ENHANCE THE THERMODYNAMIC PERFORMANCE OF A 285MW GAS TURBINE UNIT
DOI:
https://doi.org/10.66411/jer.v26i.320Keywords:
Gas turbine, Ejector, Entrainment ratio, Steam injection, Performance enhancementAbstract
The performance of gas turbines, mainly the output power and efficiency, are affected considerably by the ambient temperature, where, they deteriorate as the ambient temperature rises. This could be a challenge especially for periods of peak load demand.One way to enhance the performance of gas turbine power plants is by injecting steam into the combustion chamber. In this work, an ejector is integrated to inject steam into the combustion chamber of a gas turbine power unit. The exhaust gases of the gas t urbine are employed as the energy source to generate the steam. For the analysis, two environmental temperatures are selected, 15oC (ISO condition) and 50oC (hot climate zone). the aim of the current work is to enhance the thermodynamic performance of an existing 285MW gas turbine unit. Results show a specific value for the entrainment ratio at which the thermal efficiency and hence the specific fuel consumption emerge optimum values
References
[1] H. K. Kayadelen and Y. Ust, “Performance and environment as objectives in multi-criterion optimization of steam injected gas turbine cycles,” Appl. Therm. Eng., vol. 71, no. 1, pp. 184–196, 2014. DOI: https://doi.org/10.1016/j.applthermaleng.2014.06.052
[2] H. Athari, S. Soltani, M. A. Rosen, S. M. Seyed Mahmoudi, and T. Morosuk, “Comparative exergoeconomic analyses of gas turbine steam injection cycles with and without fogging inlet cooling,” Sustain., vol. 7, no. 9, pp. 12236–12257, 2015. DOI: https://doi.org/10.3390/su70912236
[3] E. Kakaras, A. Doukelis, and S. Karellas, “Compressor intake-air cooling in gas turbine plants,” Energy, vol. 29, no. 12–15 SPEC. ISS., pp. 2347–2358, 2004. DOI: https://doi.org/10.1016/j.energy.2004.03.043
[4] R. Hosseini, A. Beshkani, and M. Soltani, “Performance improvement of gas turbines of Fars (Iran) combined cycle power plant by intake air cooling using a media evaporative cooler,” Energy Convers. Manag., vol. 48, no. 4, pp. 1055– 1064, 2007. DOI: https://doi.org/10.1016/j.enconman.2006.10.015
[5] N. Lior, “A Novel High-Temperature Ejector- Topping Power Cycle,” J. Eng. Gas Turbines Power, vol. 1, no. JANUARY, pp. 1–7, 1994. DOI: https://doi.org/10.1115/1.2906793
[6] H. Canière, A. Willockx, E. Dick, and M. De Paepe, “Raising cycle efficiency by inter-cooling in air-cooled gas turbines,” Appl. Therm. Eng., vol. 26, no. 16, pp. 1780–1787, 2006. DOI: https://doi.org/10.1016/j.applthermaleng.2006.02.008
[7] F. N. M. Elwekeel and A. M. M. Abdala, “Effect of mist cooling technique on exergy and energy analysis of steam injected gas turbine cycle,” Appl. Therm. Eng., vol. 98, pp. 298–309, 2016. DOI: https://doi.org/10.1016/j.applthermaleng.2015.12.040
[8] B. Mohanty and G. Paloso, “Enhancing gas turbine performance by intake air cooling using an absorption chiller,” Heat Recover. Syst. CHP, vol. 15, no. 1, pp. 41–50, 1995. DOI: https://doi.org/10.1016/0890-4332(95)90036-5
[9] Y. S. H. Najjar, “Enhancement of performance of gas turbine engines by inlet air cooling and cogeneration system,” Appl. Therm. Eng., vol. 16, no. 2, pp. 163–173, 1996. DOI: https://doi.org/10.1016/1359-4311(95)00047-H
[10] M. M. Alhazmy, R. K. Jassim, and G. M. Zaki, “Performance enhancement of gas turbines by inlet air-cooling in hot and humid climates,” Int. J. Energy Res., vol. 30, no. 10, pp. 777–797, 2006. DOI: https://doi.org/10.1002/er.1184
[11] A. M. Al-Ibrahim and A. Varnham, “A review of inlet air-cooling technologies for enhancing the performance of combustion turbines in Saudi Arabia,” Appl. Therm. Eng., vol. 30, no. 14–15, pp. 1879–1888, 2010. DOI: https://doi.org/10.1016/j.applthermaleng.2010.04.025
[12] S. Bahrami, A. Ghaffari, M. Genrup, and M. Thern, “Performance comparison between steam injected gas turbine and combined cycle during frequency drops,” Energies, vol. 8, no. 8, pp. 7582–7592, 2015. DOI: https://doi.org/10.3390/en8087582
[13] M. De Paepe and E. Dick, “Cycle improvements to steam injected gas turbines,” Int. J. Energy Res., vol. 24, no. 12, pp. 1081–1107, 2000. DOI: https://doi.org/10.1002/1099-114X(20001010)24:12<1081::AID-ER641>3.0.CO;2-6
[14] I. A. Elfeituri, “Thermodynamic performance of a 285 MW gas turbine unit under varying operating conditions,” J. Eng. Res. (University Tripoli, Libya), no. 23, pp. 145–162, 2017.
[15] G. M. Fellah, “Effect of Ambient Temperature on the Thermodynamic Performanc of a Combined Cycle,” J. Eng. Res., no. 13, pp. 35–48, 2010.
Downloads